Systema accumulationis energiae 30.72 kWh, fasciculus accumulatoris LiFePO4
STRUCTURA DIVISIO SYSTEMATIS
PARAMETRI TECHNICI
| Modellum | Configuratio | |||
| ESS12048E600P4 | MPPT-SCM 48240R | INVERSOR-HP 12048DR | BATTERIA-LFP 48200R*3 | Energia totalis |
| 240A (60A*4) | 12 kW | 600AH (200AH * 3) | 30.72 kWh | |
| Batteria | Descriptio | |||
| Specificatio normalis | ||||
| 1 | Tensio Aestimata | 51.2V | ||
| Duo | Capacitas Aestimata | 600Ah | ||
| Tres | Energia Aestimata | 30.72 kWh | ||
| quattuor | Configuratio Batteriae | 10.24 kWh (16S2P) * 3 partes | ||
| quinque | Cellula Batteriae | 3.2V100AH 96 partes | ||
| Pretium Ordinarium | ||||
| 1 | Ambitus temperaturae operationis @ impletio | 0~45℃ | ||
| Duo | Tensio oneris aestimata | 55.2±0.4V | ||
| Tres | Maxima tensio oneris | 56.8±0.4V | ||
| quattuor | Protectio contra nimium onus | 58.4±0.4V | ||
| quinque | Maxima cursus electricus permissus (Summa) | 330A sustinent 30s (omnis sarcina 110A) | ||
| sex | Currens oneris maximi (Summa) | 360A sustinent 5s (omnis sarcina 120A) | ||
| VII | Currens oneris aestimatus (Summa) | 300A (quisque fasciculus 100A) | ||
| VIII | Currens electricus commendatus (Summa) | |||
| Emissio ordinaria | ||||
| 1 | Ambitus temperaturae operationis @ exoneratio | -20~60℃ | ||
| Duo | Ambitus Tensionis Egressus | 40~56Vdc | ||
| Tres | Spatium Laboris Commendatum | 46~54Vdc | ||
| quattuor | Tensio interclusiva exonerationis | 40V | ||
| quinque | Maxima emissio fluxus permissa (Summa) | 660A sustinere 30s (quaeque sarcina 220A) | ||
| sex | Summa fluxus exonerationis (Summa) | 720A sustinere 5s (omnis sarcina 240A) | ||
| VII | Currens exonerationis aestimatus (Summa) | 600A (quisque fasciculus 200A) | ||
| VIII | Currens exonerationis commendatur (Summa) | |||
| Communicatio | ||||
| 1 | RS485 | Pro LCD remoto | ||
| Duo | POSSUM | Imperium et monitorium computatrale | ||
| Invertor (intus) | Descriptio | |||
| Specificatio normalis | ||||
| 1 | Potentia Aestimata | 12 kW | ||
| Duo | Forma Undae Egressus | Unda Sinusoidali Pura/Idem ac ingressum (Modus Praetermissionis) | ||
| Tres | Tensio Egressus | 240Vac(HH)/120Vac(HN) ±10% RMS | ||
| quattuor | Frequentia Emissionis | 50 vel 60± 0.3Hz (Modus inversoris per ordinationem sw4) | ||
| quinque | Tempus Translationis Typicum | 4-6ms typica, 10ms (max.) | ||
| sex | THD | |||
| VII | Ambitus Input AC | 184-253Vac (modus UPS) vel 140-270Vac (modus GEN) | ||
| VIII | Caricator AC personalizatus | Positio selectoris generis pilae 9, designatio specialis pro LFP, vitam cycli pilae maximizat. | ||
| IX | Maxima Cursus Oneris AC | 100A | ||
| decem | Functio prioritatis pilae | Constitutio per SW5 in positione 1 (modus inversoris validus), AC automatice intervenit cum tensio pilae humilis ad 48Vdc vel 50Vdc alarmum emittit. | ||
| undecim | Deviatio AC sine impletione | Positio selectoris generis pilae 0 | ||
| MPPT (intus) | Descriptio | |||
| Specificatio normalis | ||||
| 1 | POTENTIA PV | 3.5 kW*4 | ||
| Duo | Tensio Ingressa PV | 60-145Vdc | ||
| Tres | Tensio Impletionis MPPT | 56.0Vdc (oneratio celeris)/54Vdc (oneratio fluctuans) | ||
| quattuor | MPPT Currens Egressus | 60A*4 | ||
| Proprietates Mechanicae | ||||
| ESS12048E600P4 | Dimensiones A*L*P | Transportatio H*W*D | Pondus (NW) | Pondus (GW) |
| 1360*560*960mm | 1540*700*1050mm | 440 kg | 480 kg | |
APPLICATIO