Regulator Tensionis Automaticus Triphasicus TNS
Proprietates Regulatoris Tensionis Automatici Triphasici (AVR) SVC (1) Regulator tensionis AC magnam capacitatem et praecisionem magnam habet (2) Technologiam tensionis compensatae adhibitam (3) Latam ambitum tensionis ingressus (4) Protectionem contra nimium tensionis (5) Auto-aequationem tensionis egressus triphasicae (moderationem individualem) (6) Regulator tensionis AC systemate praetervectionis instructus est (7) Ostentus LCD/LED/Analogicus omnes praesto sunt (8) AVR instrumentum electronicum necessarium in systemate copiarum electricarum est.
Parametri Regulatoris Tensionis Automatici Triphasici SVC (TNS: 1.5KVA~15KVA)
| Specificatio AVR | TNS-1.5KVA | TNS-3KVA | TNS -4.5KVA | TNS -6KVA | TNS -9KVA | TNS -15KVA | |
| Inputum | Phase | Triphasis | |||||
| Tensio electrica | AC 260V-430V | ||||||
| Frequentia | 50Hz/60Hz | ||||||
| Exitus | Tensio electrica | 380V ± 3% | |||||
| Capacitas | 1.2 kW | 2.4 kW | 3.6 kW | 4.8 kW | 7.2 kW | 12 kW | |
| Frequentia | 50Hz/60Hz | ||||||
| Protectio | Tensio humilis | 318V±7V | |||||
| Supertensio | 426V±7V | ||||||
| Calor nimium | Facultativum | ||||||
| Systema refrigerationis | Systema refrigerationis naturalis (ad libitum) | ||||||
| Brevis phasis | ITA | ||||||
| Mora Temporis | 3-7 sec/3-7 min (Selegibile) | ||||||
| Praetermissio | Automaticus/Manualis (Optionalis) | ||||||
| Onus nimium/circuitus brevis | ITA | ||||||
| Involucrum | Peciae per Scatolam | 1 | |||||
| Pondus Transportationis (Kg) | XV | 18.3 | 18.75 | 31.5 | 38.9 | 89.75 | |
| Dimensiones sarcinae (mm) | 530*370*205 | 380*390*795 | 450*490*940 | ||||
| Efficacia | AC-AC | >95% | |||||
| Acoustica | Gradus sonitus | ≤50dB | |||||
| Ambitus | Temperatura | -5°C ad 45°C | |||||
| Humiditas | 20% ad 90% | ||||||
| Quantitas (unc.) | XX pedes | DCC | DCC | DCC | 238 | 238 | 135 |
Parametri Regulatoris Tensionis Automatici Triphasici SVC (TNS: 20KVA~90KVA)
| Specificatio | TNS-20KVA | TNS-30KVA | TNS-45KVA | TNS-60KVA | TNS-75KVA | TNS-90KVA | |
| Inputum | Phase | Triphasis | |||||
| Tensio electrica | AC 276V-430V | AC 304V-456V | |||||
| Frequentia | 50Hz/60Hz | ||||||
| Exitus | Tensio electrica | 380V ± 3% | |||||
| Capacitas | 16 kW | 24 kW | 36 kW | 48 kW | 60 kW | 72 kW | |
| Frequentia | 50Hz/60Hz | ||||||
| Protectio | Tensio humilis | 318V±7V | |||||
| Supertensio | 426V±7V | ||||||
| Calor nimium | Facultativum | ||||||
| Systema refrigerationis | Systema refrigerationis naturalis (ad libitum) | ||||||
| Brevis phasis | ITA | ||||||
| Mora Temporis | 3-7 sec/3-7 min (Selegibile) | ||||||
| Praetermissio | Automaticus/Manualis (Optionalis) | ||||||
| Onus nimium/circuitus brevis | ITA | ||||||
| Involucrum | Peciae per Scatolam | 1 | |||||
| Pondus Transportationis (Kg) | 94.55 | 107.25 | 138.2 | 149.05 | 271.2 | 295 | |
| Dimensiones sarcinae (mm) | 570*510*1055 | 675*655*1115 | 850*790*1530 | ||||
| Efficacia | AC-AC | >95% | |||||
| Acoustica | Gradus sonitus | ≤50dB | |||||
| Ambitus | Temperatura | -5°C ad 45°C | |||||
| Humiditas | 20% ad 90% | ||||||
| Quantitas (unc.) | XX pedes | Nonaginta | Nonaginta | viginti | viginti | XIV | XIV |
Nos sumus praecipui opifices regulatorum tensionis triphasici SVC in Sinis, in fabricatione et venditione variorum generum regulatorum tensionis, UPS offline, et oneratorum accumulatorum, ut pauca tantum commemorem, periti. Propter seriem completam, qualitatem certam et pretia rationabilia, producta nostra magis magisque in Russia, Asia Meridionali-Orientali, Africa, aliisque locis adhibentur. Si productis electricis similibus opus est, nobiscum contactum facere libenter potes!